Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 649-653, 2021.
Article in Chinese | WPRIM | ID: wpr-912340

ABSTRACT

Objective:To investigate the common types, surgical treatment and effects of tracheal stenosis in children.Methods:A total of 23 children with tracheal stenosis in our hospital from December 2017 to August 2020 were retrospectively reviewed, including 14 males and 9 females. The mean age at operation was(8.9±5.8)months(range: 2-3 months) and the mean weight was(6.4±2.3)kg(range: 4.2-10.5 kg). The common types of tracheal stenosis were complete tracheal ring in 9 children, tracheomalacia in 10 and subglottic membranous annular hyperplasia in 4. The type of congenital heart diseases included 10 patients of pulmonary artery sling, 1 of tetralogy of Fallot, 5 of ventricular septal defect, 1 of pulmonary atresia, and 1 of right aortic arch with aberrant left subclavian artery. Slide tracheoplasty was performed in 9 patients, external splint in 8, endotracheal stent in 2 and tracheal dilation in 4. All children were followed up after 1, 3, 6, and 12 months of operation with CT and bronchoscopy.Results:There was 1 death in all 23 patients and the mortality was 4.3%, which died of granulation tissue hyperplasia after slide tracheoplasty. Reoperation was performed in 1 patient with endotracheal stent. All patients were followed for 1 to 24 months. Clinical symptoms of tracheal stenosis disappeared and the results of CT and bronchoscopy were satisfied.Conclusion:Slide tracheoplasty is the effective surgical method for complete trachea ring. 3D printing bioresorbable external splint is a promising method for the treatment of tracheomalacia.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 577-579, 2017.
Article in Chinese | WPRIM | ID: wpr-667363

ABSTRACT

Objective To explore the feasibility of percutaneous puncture for ventricular septal defect(VSD).Methods From March 2015,we did percutaneous punctured transcatheter device closure of VSD for 22 patients.The patients included 15 males and 7 females with age from 2 years 6 months to 11 years 7 months, weight from 13.5 kg to 44.0 kg.Among 22 pa-tients,6 were diagnosed with residual shunt after VSD repair, with size of residual shunt from 4.8 mm to 7.0 mm.Residual shunts are perimembranous, conoventricular and intracristal.The other 16 patients were diagnosed with isolated VSD,with de-fect size from 3.5 to 5.1 mm.For all patients,we punctured directly through the right ventricular surface into the right ventri-cle in the 3th or 4th intercostal space of the left sternal border.Next, we succeeded to extract the guide wire after inserting a conveyor tube for 21 patients.Subsequently,7-10 mm VSD closure device were delivered via the conveyor tube.Only one patient was changed to perform occlusion of VSD through chest small incision due to improper selection of punctured position. Results A total of 21 closure devices were placed for 21 patients.18 of them are equilateral device,and 3 are decentered de-vice,with size from 5 mm to 10 mm.There were small amount of pericardial effusion in 4 patients using TEE examination,and no future treat was performed after observation.For one-year follow-up, all patients have recovered very well.Conclusion Percutaneous punctured transcatheter device closure fits for treatment for children with residual shunt after VSD repair and isola-ted VSD.It has a good recent result.

3.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 539-541, 2017.
Article in Chinese | WPRIM | ID: wpr-662831

ABSTRACT

Objective To explore the feasibility of hybrid procedure of percutaneous puncture for residual shunt after ventricular septal defect(VSD) repair.Methods From March 2015,we did percutaneous punctured transcatheter device closure of residual shunt after VSD repair for four patients.The patients included 2 males and 2 females with age from 4 years 9 months to 11 years 7 months and weight from 18 kg to44 kg.Four patients are diagnosed for4 years after VSD repair,3 years after tetralogy of Fallot (TOF),3 years after coarctation of aorta(CoA) combined with VSD,and 1 year after VSD repair,respectively.The withsize of residual shunt from 4.8 mm to 6.8 mm.Residual shunt are perimembranous,conoventricular and intracristal.Punctured directly through the right ventricular surface into the right ventricle in the 4-th or 5th intercostal space of the left sternal border.Next,extracted the guide wire after inserting a conveyor tube.Subsequently,7-10 mm VSD closure device were delivered via the conveyor tube.Results All the four operations were succeeded.A total of four closure devices were placed.Two of them are equilateral devices,and two are decentered devices,with size from 7mm to 9mm.Echocardiographyexamination revealed no significant pericardial effusion.Post-operative ultrasonic cardiogram showed the VSD closure device on site,with no pericardia1 effusion and no obvious morphological abnormalities of the valve.For one-year follow-up,the cardiac functionsof all patients were well.Conclusion Percutaneous punctured transcatheter device closure is a new,efficient and reliable method of treatment for children withresidual shunt after VSD repair.This method also can extend and offer a new avenue for valvular prosthesis and Perimembranous VSD.

4.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 539-541, 2017.
Article in Chinese | WPRIM | ID: wpr-660830

ABSTRACT

Objective To explore the feasibility of hybrid procedure of percutaneous puncture for residual shunt after ventricular septal defect(VSD) repair.Methods From March 2015,we did percutaneous punctured transcatheter device closure of residual shunt after VSD repair for four patients.The patients included 2 males and 2 females with age from 4 years 9 months to 11 years 7 months and weight from 18 kg to44 kg.Four patients are diagnosed for4 years after VSD repair,3 years after tetralogy of Fallot (TOF),3 years after coarctation of aorta(CoA) combined with VSD,and 1 year after VSD repair,respectively.The withsize of residual shunt from 4.8 mm to 6.8 mm.Residual shunt are perimembranous,conoventricular and intracristal.Punctured directly through the right ventricular surface into the right ventricle in the 4-th or 5th intercostal space of the left sternal border.Next,extracted the guide wire after inserting a conveyor tube.Subsequently,7-10 mm VSD closure device were delivered via the conveyor tube.Results All the four operations were succeeded.A total of four closure devices were placed.Two of them are equilateral devices,and two are decentered devices,with size from 7mm to 9mm.Echocardiographyexamination revealed no significant pericardial effusion.Post-operative ultrasonic cardiogram showed the VSD closure device on site,with no pericardia1 effusion and no obvious morphological abnormalities of the valve.For one-year follow-up,the cardiac functionsof all patients were well.Conclusion Percutaneous punctured transcatheter device closure is a new,efficient and reliable method of treatment for children withresidual shunt after VSD repair.This method also can extend and offer a new avenue for valvular prosthesis and Perimembranous VSD.

SELECTION OF CITATIONS
SEARCH DETAIL